ADAS Subroutine ccaval
SUBROUTINE CCAVAL(NUPPER,NLOWER,AVALUE)
C-----------------------------------------------------------------------
C
C ********* FORTRAN77 SUBROUTINE: CCAVAL *********
C
C PURPOSE: EVALUATES HYDROGENIC TRANISITON PROBABILITIES
C FOR TRANSITIONS BETWEEN PRINCIPAL QUANTUM SHELLS.
C
C CALLING PROGRAM: ADAS312
C
C INPUT :
C
C (I*4) NUPPER : UPPER PRINCIPAL QUANTUM
C NUMBER.
C (I*4) NLOWER : LOWER PRINCIPAL QUANTUM
C NUMBER.
C
C OUPUT :
C (R*8) AVALUE : TRANSITION PROBABILITY.
C
C GENERAL :
C
C (R*8) EN : UPPER PRINCIPAL QUANTUM
C NUMBER.
C (R*8) EN1 : LOWER PRINCIPAL QUANTUM
C NUMBER.
C (R*8) X2 : GENERAL VARIABLE
C (R*8) X : GENERAL VARIABLE
C (R*8) G : BOUND-BOUND GAUNT FACTOR.
C
C
C ROUTINES:
C
C ROUTINE SOURCE BRIEF DESCRIPTION
C ------- ------ -----------------
C GBB ADAS EVALUATES BOUND-BOUND
C GAUNT FACTOR.
C
C CONTACT : HARVEY ANDERSON
C UNIVERSITY OF STRATHCLYDE
C ANDERSON@PHYS.STRATH.AC.UK
C
C DATE : 11/03/99
C
C VERSION: 1.1 DATE: 17-03-99
C MODIFIED: HARVEY ANDERSON
C - FIRST VERSION
C
C-----------------------------------------------------------------------
INTEGER NLOWER, NUPPER
REAL*8 AVALUE